Re-config IP500 w/DTE

The DTE port on the back of an IP Office Control Unit is not normally used when configuring an IP Office system. However the DTE port can be used to erase the system’s operational software and/or configuration if necessary.

Due to the drastic nature of these actions they should only be performed if absolutely necessary to return a system back to working order. In either case you must ensure that you have a backup copy of the system configuration.

 

Access to the DTE port requires a serial cable between your PC/Laptop and the IP Office (such as a standard modem cable).

  • DTE PORT on 403 & 406v1 units: 25 pin.
  • DTE PORT on SOE, 406v2 & 412 units: 9 pin

Also required is an asynchronous terminal program such as HyperTerminal

Configure the terminal program as follows:

  • Bits per second: 38,400.
  • Data bits: 8.
  • Parity: None.
  • Stop Bits: 1.
  • Flow Control: None.
  • Settings | Emulation: TTY or VT100.

 

It may sometimes be necessary to find out the version of Loader software on the IP Office Control Unit.

  1. Switch off power to the IP Office Control Unit.
  2. Attach the serial cable between the PC and the DTE port on the IP Office Control Unit.
  3. Start the terminal program on your PC. Ensure that it has been setup as listed in DTE Port Settings above.
    (within the terminal program, the current settings are summarized across the base of the screen).
  4. Power on the IP Office Control Unit and press the escape key every second until you get a Loader message. Example:
  5. To return the IP Office Control Unit to normal operation switch power to it off and then back on.
  6. Close the terminal program session

 

This process erases the configuration held in the IP Office Control Unit’s Flash memory. Following this action, when rebooted all aspects of the configuration will be return to their factory defaults.  MAKE SURE YOU HAVE A BACKUP.

  1. Switch off power to the IP Office Control Unit.
  2. Attach the serial cable between the PC and the DTE port on the IP Office Control Unit.
  3. Start the terminal program on your PC. Ensure that it has been setup as listed in DTE Port Settings above.
    (within the terminal program, the current settings are summarized across the base of the screen).
  4. Power on the Control Unit and press the escape key every second until you get a Loader message.
  5. Enter AT (note upper case). The Control Unit should respond OK.
  6. Enter AT-X2. The Control Unit should respond 0x0200C000H Erase.
  7. Enter AT-X3. The Control Unit should respond 0x02001000H Erase.
  8. Switch power to the Control Unit off and then back on.
    Within the terminal program, you should see various messages as the Control Unit performs various start up tasks.
  9. Close the terminal program session.
  10. You can now use Manager to alter and then upload an old configuration file or receive and edit the Control Unit’s now defaulted configuration.

 